Verified Mechanical Conformance to European Standard EN 622-5
Full technical disclosure of test methodologies governed by EN 622-5 for load-bearing and general-purpose interior applications.
| Property & Test Method | الوحدة | EN 622-5 Threshold | WOTECH Result (16 mm) | Variance / Margin | Conformance |
|---|---|---|---|---|---|
|
Internal Bond Strength (IB)
Tensile strength perpendicular to plane • Test Method: EN 319
Demonstrating internal fiber cohesion after continuous hot pressing. |
N/mm² | ≥ 0.55 |
0.72
|
+30.9% above spec | PASSED |
|
Bending Strength (MOR)
Modulus of Rupture • Test Method: EN 310
Resistance to structural loads and transverse bending moments under service conditions. |
N/mm² | ≥ 20.0 |
26.8
|
+34.0% above spec | PASSED |
|
Modulus of Elasticity (MOE)
Bending stiffness • Test Method: EN 310
Rigidity and deflection resistance under sustained weight and structural spans. |
N/mm² | ≥ 2,200 |
2,840
|
+29.1% above spec | PASSED |
|
Thickness Swelling (24h Immersion)
Water absorption & dimensional expansion • Test Method: EN 317
Dimensional stability and water-resistance metrics under direct 24-hour liquid immersion. |
% | ≤ 12.0 |
8.6 %
|
-28.3% lower swelling (Superior) | PASSED |
|
Surface Soundness
Micro-surface bonding strength • Test Method: EN 311
Micro-surface tension ensuring zero delamination during lamination and direct finishing. |
N/mm² | ≥ 0.80 |
1.18
|
+47.5% above spec | PASSED |
|
Screw Holding Capacity (Face & Edge)
Fastener pull-out resistance • Test Method: EN 320
Fastener pull-out resistance for hinges, structural cam-locks, and cabinetry fittings. |
Newton (N) |
Face: ≥ 950 N
Edge: ≥ 800 N
|
Face: 1,240 N
Edge: 1,060 N
|
+30.5% (Face) / +32.5% (Edge) | PASSED |
In-Line Plant Quality Control
Precision quality control embedded directly within the Siempelkamp continuous-press sequence, monitored 24/7 by the Edku Quality Lab.
Real-Time Ultrasonic Delamination Detection
Automated continuous blow-detection scanners monitoring every linear meter of board emerging from the Siempelkamp press.
Radiometric Density Profile Scanners
Continuous cross-sectional density profiling ensuring high face density and solid core integrity.
Automated Sanding & Calibrating
Precision surface tolerances within ±0.1 mm across both board faces.
Verified Document Download Center
Access authentic certified compliance certificates and laboratory test results issued by accredited quality laboratories.